Pharmacy-new.org specialises in selling drugs and other medicines that improve the health and well being of the entire family. We have over 5500 medicines available and our customers grows rapidly. We are selling medicines all over the world. The Pharmacy-new.org website also offers a wealth of information on health care and medicine. Our mission is to ensure that all people have access to high-quality medical care at all times through innovative technologies at affordable cost.

+ Fast delivery Worldwide
+ Best prices lowest prices for all medicine

Accu Chek Active 50 test strips

Test strips for quantitative measurement of glucose in fresh capillary and anticoagulated with Li- or HN3- heparin or EDTA venous blood, and if the blood is placed outside the meter - arterial and neonatal blood.
Only be used with blood glucose Accu-Chek Active, Accu-Chek Plus or Glucotrend within a measuring range of 10-600 mg / dl (0,6-33,3 mmol / L)
Suitable for self


Self-monitoring of blood glucose provides you with additional security daily and recording the results in your journal or notebook helps the doctor to examine how to maintain your blood sugar. Self-control can not replace regular visits to the doctor. Before you begin, keep in mind that self-control required to be adequately trained by qualified medical personnel. Your healthcare team will determine individually expedient range of blood glucose values with you.

Take time to read the user manual for your meter Accu-Chek Active, Accu-Chek Plus or Glucotrend, before you start working with him. The User Guide contains all information necessary to perform blood sugar testing.

If you think the results of blood sugar levels are too low or too high, or if you awaken suspicion, contact your doctor.

If you are a patient on peritoneal dialysis, talk to your doctor before you measure your blood sugar. The solution for dialysis can lead to falsely increase your results. Such false results may lead to wrong therapeutic decision and hence to negative health effects.

The cap of the test strip container comprises a non-toxic desiccant silica. If you accidentally swallow it, drink plenty of water. If you have any questions, please contact our center for help and customer service.

All the things that are contained in the package can be disposed of with normal household waste.

Since the ingredients were in small quantities, according to the regulations of the European Union, they are not considered dangerous substances. If you have any questions, please contact our center for help and customer service.

The test strip contains no toxic substances, so there is no danger if the test tap area when inserting the blood.

Evidence

This product is designed to check the blood sugar levels in patients with diabetes, self-control blood sugar in people with diabetes, in cases of suspected diabetes and emergency diagnosis.


Package Contents

1 container with test strips and 1 label color chart table concentrations and code number
1 encoding chip
1 leaflet

To determine blood sugar are needed

Meter Accu-Chek Active, Accu-Chek Plus or Glucotrend c User Guide
Lancet (lancet) device and lancets

Blood volume and time of measurement Meter Accu-Chek Active:

The meter requires 1-2 microliters of blood (mikrolita = 1 thousandth of a milliliter) to a measurement of blood sugar. If the amount of the applied blood is not enough, you can put 5 seconds after the second drop of blood. If the test strip into the meter in the implementation of the blood, the measuring time is about 5 seconds. If the test strip is outside the meter when applying the blood, the measuring time is about 10 seconds.

Glucometers Accu-Chek Plus and Glucotrend:

Glucose monitors require at least two microliters of blood for one measurement of blood sugar. The measuring time is required 10 seconds.

Coding

Each pack of test strips contains a code chip. This code chip contains information for certain test strips needed by the meter to determine the measurement result. The code chip applies only to these test strips. After opening a new pack of test strips, you need to remove the old code chip from the meter and replace it with the new coding chip from the new pack. Remove the old code chip from the meter. Insert the new code chip directly and without application of force slot coding chip side of the meter. You should feel the code chip lock into place. The new code chip remains lyukomera until you open a new pack of test strips.

Always change the code chip when you open a new pack of test strips. Make sure that the three-digit code printed on the code chip is the same as the code printed on the label of the test strip container. Wrong code chip or code can lead to incorrect results. Such false results may lead to wrong therapeutic decision and hence to negative health effects.


Proper storage and use of test strips


Test strips that are stored in extremely hot or cold conditions or who have long been exposed to high humidity - money or condensed liquid - may give false results Ido. Such false results may lead to wrong therapeutic decision and hence to negative health effects.
Always keep the test strips in their original container and keep the container tightly closed.
Keep test strips at between +2 and +30 ° C in a dry place away from direct sunlight.
Do not carry out the test in direct sunlight.
Test strips are sensitive to humidity - money and condensed liquid. Do not remove the test strip container around with wet hands. Always close the test strip container with the original cap tightly immediately after removing the test strip. The cap of the test strip container comprises a hygroscopic agent that protects the test strips from moisture. If the test strip container penetrate moisture from your hands or if the cap is left not closed for long periods, hygroscopic agent no longer works. When transporting test strips, always keep them in a tightly closed container.
Use test strips only in date. Test strips that have expired, can give incorrect results. The expiry date is printed after 62 symbols on the packaging and on the label of the test strip container. In proper handling and storage, test strips from new nerazpechatan container with test strips and test strips that are already open can be used to print the date of the expiry date.
When performing the test, the temperature should be between +10 and +40 ° C
Test strips have reached room temperature when testing blood glucose test strips that are stored in the refrigerator, you need to remove the container from the refrigerator and leave it in the closed position to stand at room temperature until warm. Do not remove the test strip before the container has reached room temperature. This will avoid the occurrence of condensation of water vapor inside the container as a result of warming.
Do not place objects such as cleaning cloths or used test strips in the container together with unused test strips. This can make test strips unusable.
You can dispose of the test strips with your household waste.

How does the test

On each test strip has a test area containing sensitive chemicals. When in this area
be put blood, a chemical reaction occurs (messenger response oxidoreductase dyeing glucose (pyrroloquinolin quinone (PHH) dependent glucose dehydrogenase messenger response)), leading to discoloration of test area. The meter measures the change in color and converts the recorded amounts due to the amount of blood sugar.

Check the result by the control window of the test strip

Test strip itself allows you judge the December by comparing colors and thus further control the displayed result. In making treatment decisions *** should be used only results that show the meter. Comparison of the color only serves as an additional check of the result.


Before the measurement

On the back of the test strip is a round colored control window. Compare the color of this window with the colored dots on the label of the container Theatre strips. The color of the control window must match that on top of the color scale (0 mg / dL, and mmoi / g. If the control panel displays OTHER nvyat should not use more tape Theatre.

After a measurement

The label on the container Theatre bands are color scale with blood glucose values in
mg / dL or mmol / L

Select the value of blood sugar! which is closest to the value received from you. Compare again within 30-60 seconds after applying the drop of blood the color of the control window on the back of the TEA strip with the color scale on the label of the container with tape Theatre.

 

 

Write a review

Your Name:

Your Review: Note: HTML is not translated!

Rating: Bad           Good

Enter the code in the box below:



Related Products
×
×
×
×

Fast delivery

Worldwide

Free advice

×

Free advice

24/7

Best prices

×

Best prices

lowest prices for all medicine

×